Tisch-Digitaloszilloskope
Frage Nr. 1 (ask on 18/07/2019) : Hello, I would like to know the oscilloscope similar to my device? Could you please help me ?
beantwortet am 19/07/2019 :
Metrix Digital Oscilloscopes |
|
Old Products |
Replacement Products |
OX6062B-CSD |
DOX2100 or OX9062 |
OX6062B-CSDO |
DOX2100 or OX9062 |
OX6202B-CSD |
DOX2100 or OX9102 |
OX6202B-CSDO |
DOX2100 or OX9102 |
OX6062B-CFG |
OX9062-CFG |
OX6202B-CFG |
OX9302-CFG |
OXI6204 |
OX9304 |
Frage Nr. 1 (ask on 24/06/2019) : Hello, I would like to know if there's a replacement item for the Qualistar and the QualistarPlus battery? Thank you.
beantwortet am 25/06/2019 :
There is a spare battery for the list of devices below:
- CA8331
- CA8332 - CA8332B
- CA8333
- CA8334 - CA8334B
- CA8335 - CA8435
- CA8336 - CA8436
The article code is identical for the battery of all these instruments: P01296024
Frage Nr. 2 (ask on 27/05/2019) : I need the user's manual of my Qualistar CA8336 in other languages than those proposed on the website. Is it possible to have them?
beantwortet am 28/05/2019 :
There are other languages for the Qualistar CA8336 user's manual:
Swedish: https://www.chauvin-arnoux.com/COM/CA/doc/Bruksanvisningar_CA8336.pdf
Chinese: https://www.chauvin-arnoux.com/COM/CA/doc/User_manual_zh_CA8336.pdf
Dutch: https://www.chauvin-arnoux.com/COM/CA/doc/Gebruikshandleiding_CA8336.pdf
Romanian: https://www.chauvin-arnoux.com/COM/CA/doc/Instructiuni_de_utilizare_CA8336.pdf
Polish: https://www.chauvin-arnoux.com/COM/CA/doc/Instrukcja_obslugi_CA8336.pdf
Finnish: https://www.chauvin-arnoux.com/COM/CA/doc/Kayttoohjeet_CA8336.pdf
Czech: https://www.chauvin-arnoux.com/COM/CA/doc/Uzivatelska_prirucka_CA8336.pdf
Russian: https://www.chauvin-arnoux.com/COM/CA/doc/User_manual_ru_CA8336.pdf
Alle Produkte
Frage Nr. 1 (ask on 24/06/2019) : Hello, I lost my connection cable of my CA8332B and CA8334B devices. As the products are no longer on your website, can I still order it?
beantwortet am 25/06/2019 :
You can order the RS232 DB9F optical cable with the code P01295190A.
If you want to connect the device with your computer through the USB port, you only need the RS232 - USB reference adapter: HX0055B.
Leistungs-, Energie, Störungs-Analysatoren
Frage Nr. 1 (ask on 24/06/2019) : Hello, I changed my computer, and since I can not connect my two CA8332B and CA8334B devices to the software, the two devices are not recognized on the computer. I am using a RS232 optical cord DB9F (supplied with the device) and a RS232 adapter - USB HX0055 under Windows 10. Do you have a solution for me?
beantwortet am 25/06/2019 :
It is indeed a driver compatibility problem of the HX0055 adapter and the operating system Windows 10, so I advise you to connect directly via an RS232 connection, or to order the replacement of the HX0055 adapter, with the reference HX0055B, and which solves this problem.
Frage Nr. 2 (ask on 18/01/2019) : I am looking for the users manual of my CA8332 Power Quality Analyzer.
beantwortet am 18/01/2019 :
Download the latest edition of the Qualistar C.A 8332B or C.A 8334B manual:
http://www.chauvin-arnoux.com/sites/default/files/download/nf-ca_8332_ca_8334_gb.pdf
Oscilloscope Scopix IV
Frage Nr. 1 (ask on 18/06/2019) : The touchscreen of my Scopix IV is inactive. Is there a solution?
beantwortet am 19/06/2019 :
Press the fullscreen key on your oscilloscope, this will reactivate the touchscreen.
Button:
Vielfachmesszangen
Frage Nr. 1 (ask on 17/06/2019) : What products do you propose to replace a AC / DC clamp meter model PAC10, PAC11 or PAC 12?
beantwortet am 18/06/2019 :
The AC / DC clamp meters PAC10, PAC11 and PAC 12 are respectively replaced by the references:
PAC 10 : P01120115 PINCE PAC 15 CVH
PAC 11 : P01120116 PINCE PAC 16 CVH
PAC12 : P01120117 PINCE PAC 17 OSCILLO.
The basic specifications (measuring range, sensitivity or input / output ratio, output connection) of these new products are identical to the previous ones. And there are some additionnal features:
- The PAC15, PAC16 and PAC17 models can be powered by battery and also by a standard micro-USB external power supply (optional)
- All references now have an automatic DC zero adjustment and an automatic standby (switchable).
AC/DC-Vielfachmesszangen
Frage Nr. 1 (ask on 17/06/2019) : What products do you propose to replace a AC / DC clamp meter model PAC20, PAC21 or PAC 22?
beantwortet am 18/06/2019 :
The AC / DC clamp meters PAC20, PAC21 and PAC 22 are respectively replaced by the references:
PAC 20 : P01120125 PINCE PAC 25 CVH
PAC 21 : P01120126 PINCE PAC 26 CVH
PAC 22 : P01120127 PINCE PAC 27 OSCILLO
The basic specifications (measuring range, sensitivity or input / output ratio, output connection) of these new products are identical to the previous ones. And there are some additionnal features:
- The PAC25, PAC26 and PAC27 models can be powered by battery and also by a standard micro-USB external power supply (optional)
- All references now have an automatic DC zero adjustment and an automatic standby (switchable).
Utilisation des appareils
Frage Nr. 1 (ask on 27/05/2019) : I need the user's manual of my instruments CA8331 and CA8333 in other languages than those proposed on the website. Is it possible to have them?
beantwortet am 28/05/2019 :
There are other languages for the Qualistar CA8331 and CA8333 user's manual:
Swedish: https://www.chauvin-arnoux.com/COM/CA/doc/Bruksanvisningar_CA8331_CA8333.pdf
Chinese: https://www.chauvin-arnoux.com/COM/CA/doc/User_manual_zh_CA8331_CA8333.pdf
Dutch: https://www.chauvin-arnoux.com/COM/CA/doc/Gebruikshandleiding_CA8331_CA8333.pdf
Romanian: https://www.chauvin-arnoux.com/COM/CA/doc/Instructiuni_de_utilizare_CA8331_CA8333.pdf
Polish: https://www.chauvin-arnoux.com/COM/CA/doc/Instrukcja_obslugi_CA8331_CA8333.pdf
Leistungs- und Energie-Qualitätsanalysatoren
Frage Nr. 1 (ask on 27/05/2019) : I need the user's manual of my CA8436 device in other languages than those proposed on the website. Is it possible to have them?
beantwortet am 28/05/2019 :
Il existe d'autres langues pour les Notices de Fonctionnement du Qualistar CA8436:
Czech: https://www.chauvin-arnoux.com/COM/CA/doc/Uzivatelska_prirucka_CA8436.pdf
Dutch: https://www.chauvin-arnoux.com/COM/CA/doc/Gebruikshandleiding_CA8436.pdf
Polish: https://www.chauvin-arnoux.com/COM/CA/doc/Instrukcja_obslugi_CA8436.pdf
Romanian: https://www.chauvin-arnoux.com/COM/CA/doc/Instructiuni_de_utilizare_CA8436.pdf
Produits obsolètes
Frage Nr. 1 (ask on 10/05/2019) : How to know the product replacing my device from the range Physical & Environmental Measurements ?
beantwortet am 10/05/2019 :
In order to choose the right product according to the one you want to replace, please refer to the table below :
Alle Produkte
Frage Nr. 1 (ask on 25/03/2019) : Hello, I would like to know if my Metrix device is remotely programmable. If so, can I have the remote programming manual?
beantwortet am 27/03/2019 :
You will find on the file available on the link below the devices that can be programmed by SCPI (or IEEE 488.2) commands, as well as their associated Remote Programming Manuals:
https://www.chauvin-arnoux.com/sites/default/files/download/remote_programming_manuals_0.pdf
Frage Nr. 1 (ask on 16/01/2019) : I need to update my FTV100 Photovoltaic installations Controller. What is the latest compatible version? Can I find it on the web?
beantwortet am 17/01/2019 :
The latest firmware version of the FTV100 tester is v3.0. You can download it on the link below:
http://www.chauvin-arnoux.com/sites/default/files/download/setup_uploadergreentest_v_3_0uo_0.zip
Frage Nr. 2 (ask on 16/01/2019) : I lost the manual instructions for my photovoltaic installations tester. Where can I download it?
beantwortet am 16/01/2019 :
The PV tester user manual is available on the link below:
http://www.chauvin-arnoux.com/sites/default/files/download/nf-ftv100-gb.pdf
Frage Nr. 3 (ask on 16/01/2019) : I changed my PC, after that I lost the GreenReport software for my FTV100 tester. Could you transfer me an executable so I can install it?
beantwortet am 16/01/2019 :
The GreenReport software is available on the link below, you can download and install it on your computer. The v4.6.1 version is compatible with operating systems: Windows 7, 8, 8.1 and 10.
Download link: http://www.chauvin-arnoux.com/sites/default/files/download/pc_software_greenreport_v_4_6_1_fmp_1.zip
Frage Nr. 4 (ask on 16/01/2019) : I lost the operating instructions of the FTV200 tester. Can you send it to me?
beantwortet am 16/01/2019 :
The operating instructions for the FTV200 Photovoltaic Tester is available on the link below:
http://www.chauvin-arnoux.com/sites/default/files/download/nf-ftv200-gb.pdf
Frage Nr. 5 (ask on 16/01/2019) : I want to update the firmware on my FTV200 Photovoltaic Tester. What is the latest version? Are there any conditions to respect before installing it?
beantwortet am 16/01/2019 :
The latest version of the FTV200 firmware is v2.0.3, in order to install it on your instrument, first make sure that you have a v2.0.2 firmware version previously installed on the tester, if it is not, update in two steps, first v2.0.2, the v2.0.3. Both versions are available on the links below:
v2.0.2: http://www.chauvin-arnoux.com/sites/default/files/download/software_ftv200_v2.0.2_en_0.zip
v2.0.3: http://www.chauvin-arnoux.com/sites/default/files/download/ftv200.v.2.0.3_en_0.zip
Frage Nr. 1 (ask on 16/01/2019) : I have a PX110 Wattmeter that still works well. However, I have lost the user manual, and I need it to check the electrical characteristics of the instrument. Could you help me on this?
beantwortet am 16/01/2019 :
The user manual for the two PX 110 and PX 120 wattmeters is available in 5 languages (French, English, German, Italian and Spanish), you can download it on the link below:
http://www.chauvin-arnoux.com/sites/default/files/download/nf_px1x0_688919b00_ed04_5l.pdf
Physikalische und Umwelt-Messungen
Frage Nr. 1 (ask on 17/12/2018) : For my measurements with the CA1510, I need the air containment indicator, the Data Logger Transfer software does not allow an automatic calculation of this indicator. Do you propose another software compatible with the CA1510?
beantwortet am 17/12/2018 :
There's the AQR software (Air Quality Report) for the calculation of air containment. It is compatible with the instrument CA1510, and it allows the recorded data acquisition, and among other features the calculation of the indicator of air containment. The AQR software is available on the link below:
Download link: http://www.chauvin-arnoux.com/sites/default/files/download/setup_1.zip
Operating Systems: Windows XP - 7 -8 - 8.1 - 10